Pellet boiler Defro Bioslim 20 kW

Product data sheet
technical information
Manufacturer Information
Name: DEFRO R. Dziubela sp. komandytowa
Address: 26-067 Strawczyn, Ruda Strawczyńska 103A, PL
Email: biuro@defrogarden.pl
Website: https://www.defro.pl
European Manufacturer: Yes
Guaranteed safe checkout

Pellet boiler Defro Bioslim 20 kW
Pellet boiler Defro Bioslim 20 kW
Nationwide Commissioning and Assembly about customer service upon request possible! Delivery is by truck and lifting platform to the curb! The boiler meets the requirements of BlmSchV2 and has the CE declaration of conformity. |
BIO SLIM – compact pellet boiler for small installation spaces and for high expectations of efficiency.
For high efficiencies A tube heat exchanger with swirlers ensures this.
The pellet hopper is located directly above the heat exchanger. This solution allows the installation of the pellet boiler in very small rooms.
Powerful and efficient pellet burner with automatic cleaning.
The tube heat exchanger with integrated turbulators ensures maximum energy yield and high boiler efficiency.
Powerful induced draft fan for the necessary negative pressure in the boiler and stabilization of combustion.
Intuitive and very simple operation of the boiler thanks to the modern APC 3 control system with touchscreen, which controls 6 pumps and two heating circuit mixers and is equipped with a factory-installed internet module.
Level sensor in the pellet container to indicate the fuel reserve and to interrupt operation so that the conveyor screw does not run empty.
Technical data: compact pellet boiler for small installation spaces
Parameters/Boiler type | Unit | 20 |
---|---|---|
fuel | - | Wood pellets with a diameter of 6 mm |
Rated power | kW | 20 |
Performance range | kW | 5.9-20.4 |
Efficiency - full load | % | 92.5 |
Efficiency - Partial load | % | 93 |
Energy efficiency class | - | A+ |
Pellet container capacity1 | kg | ~126 |
Max. permissible operating pressure | bear | 3 |
Required chimney draft | Pa | 12 |
Exhaust gas temperature | °C | 82 |
Exhaust gas mass flow | g/s | 17 |
Boiler weight2 | kg | 380 |
CO2 content | % | 11.2 |
Cross-section of the chimney brick | cm x cm | min. 14x14 |
Cross-section of the chimney brick | O mm | min. 150 |
Minimum chimney height | m | 7 |
Flow/return connection | Customs | AG 1¼ / IG 1¼ |
Exhaust connection | mm | 130 |
Power supply | V/Hz | ~230/50 |
Minimum return temperature | °C | 55 |
Flow temperature min./max. | °C | 65/80 |
Sound level | dB | <75 |